| Sign In | Join Free | My bjjsgy.com | 
              
  | 
      
Brand Name : ANSHI
Model Number : AS-STB-BOX-10-4
Certification : SGS, ISO9001
Place of Origin : China
MOQ : 10
Price : Negotiable
Payment Terms : D/P, D/A, L/C, T/T, Western Union, MoneyGram
Supply Ability : 10000PCS/WEEK
capacity : 10 pairs STB module
protection level : IP55
Protection : Over-voltage
Environment : indoor or outdoor
external Size : 248*210*70
Installation : Wall or Pole
ANSHI 10 Paris external Distribution Terminal STB Module Box with grounding wire Din rail
| Main Features | 
|  			 Made of highly impact resistant ABS  			 |  		
| Protection IP 56 | 
| Smallest distribution box designed for outdoors | 
| Easy operation and wide range of wire | 
|  			 Technical Parameters  			 |  		
| Working temperature: -20℃ ~ 40℃ | 
| Storage temperature: -25℃ ~55℃ | 
| Relative humidity: ≤85%(+30℃) | 
| Atmospheric pressure: 70kPa ~106kPa | 
| Appearance: the color of all metal and plastic parts is uniform, without any scratch, rust, crusting and cracks. | 
| The labels are clear and complete. | 
| Insulation resistance: under normal ambient conditions, after high temperature test, low temperature test, temperature varing test and humidity heat test, the insulation resistance between any two independent contacts, and/or between contacts and metal parts ≥ 1000MΩ | 
| Contact resistance between contacts: under normal ambient conditions, the contact resistance between contacts ≤7 mΩ. After high temperature test, low temperature test, temperature varing test and humidity heat test, the increasing resistance ≤3 mΩ And after inserting the connection cord (or test cord) into the module for 200 times, the increasing resistance ≤3 mΩ | 
| Contact resistance between conductor and contact: under normal ambient conditions, the contact resistance between contacts ≤3 mΩ. After high temperature test, low temperature test, temperature varing test and humidity heat test, the increasing resistance ≤2 mΩ. And after terminating for 200 times, the increasing resistance ≤2 mΩ. | 
| Dielectric strength: under normal ambient conditions, after high temperature test, low temperature test, temperature varing test and humidity heat test, the insulation resistance between any two independent contacts, and/or between contacts and metal parts is able to withstand an AC voltage of of 1000V (virtual value) at 45Hz~60Hz sinowave for 1 minute, without spark over and flying arc | 
| Gas tight performance: contact touches the conductor at both sides, and thus forming the gas tight area, while the area of gas tight occupies ≥50% of the touched area on each side. | 
| Conductor diameter range: 0.32mm-0.6mm, while insulation ≤ 1.4mm | 
| Pulling strength:≥25N while pulling from the vertical side of the contacts | 
| Flame retardant performance: all plastic parts are flame retardant, reaching grade of UL FV0 | 
| Life circle: ≥200 times | 
  
 
| 
                                             | 
                
                        ANSHI 10 Paris External Distribution Terminal STB Module Box With Grounding Wire Din Rail Images |